ASTM F1947-04
$35.00
Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits
standard by ASTM International, 04/01/2004
Description
1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits (4 to 15 in. diameter) by the insertion of a folded PVC pipe, which is heated, pressurized, and expanded against the interior surface of an existing pipe with either a mechanical rounding device or steam pressure. The finished PVC pipe will be continuous and conform to the existing conduit. This rehabilitation process can be used in a variety of gravity applications, such as sanitary sewers, storm sewers, and process piping.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Product Details
- Published:
- 04/01/2004
- Number of Pages:
- 5
- File Size:
- 1 file , 67 KB
- Redline File Size:
- 2 files , 110 KB
- Note:
- This product is unavailable in Russia, Ukraine, Belarus