Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods – Glow-wire flammability test method for end-products (GWEPT)
standard by International Electrotechnical Commission, 02/06/2014

PDF FormatPDF FormatMulti-User-AccessMulti-User AccessPrintablePrintableOnline downloadOnline Download
Category:

Description

NEW! IEC 60695-2-11:2014 is available asIEC Standards+ 60695-2-11:2014 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60695-2-11:201 4 specifies a test method on an end product. It is intended to simulate the effects of thermal stresses produced by an electrically heated source to represent a fire hazard. This test method is used to check that, under defined test conditions, an end product exposed to an electrically heated source has either a limi ted ability to ignite or, if it ignites, a limited ability to propa gate flame. However, the fire hazard analysis, the flammability aspects and the flame spreading to other products are not covered by the present standard. This second edition of IEC 60695-2-11 cancels and replaces the first edition of IEC 60695-2-11 published in 2000. It constitutes a technical revision. The main changes with respect to the previous edition are:
– the Introduction has been added to provide background and how it relates to the Scope,
– the Scope has been modified for greater clarity and reference to basic safety publications,
– numerous terms and definitions relevant to this Standard have been added to Clause 3,
– the application of “small parts” and “insignificant mass” have been introduced and clarified,
– the different types of specimens, how to specify them, and limitations of the test method have been further clarified in Clause 4,
– clarified in Clause 5 the distance to specified layer when unknown,
– the information from Clause 6 has been moved into the test procedure in Clause 8,
– the conditioning of the specified layer and the laboratory ambient test conditions were clarified in Clause 7,
– measurement of the maximum flame height was removed from Clause 9,
– the reference to this test as “GWEPT” was introduced along with an applicable title change and
– Annex A has been revised to reflect current practice by prominent product committees.
This standard has the status of a basic safety publication in accordance with IEC Guide 104 and ISO/IEC Guide 51. This standard is to be used in conjunction with IEC 60695-2-10. Key words: Glowing/hot-wire, Glow wire, Flammability, Fire hazard

Product Details

Edition:
2.0
Published:
02/06/2014
Number of Pages:
30
File Size:
1 file , 310 KB
Redline File Size:
2 files , 1.4 MB
Note:
This product is unavailable in Ukraine, Russia, Belarus